Hardware fault warnings
When the management interface detects that a hardware component can't be read and automatic recovery has failed, or that there is a problem with the panel or the model data, it shows a red warning at the top of every page. The warning stays visible and disappears automatically once the component is working again. You don't need to close it.
Warning types
Orientation sensor (G-sensor) fault
The orientation sensor was not detected. Automatic recovery was attempted but did not succeed. The screen may not rotate automatically. Restart the device; if this message still appears after restarting, contact technical support.
Impact:
- The image doesn't rotate automatically when you turn the device.
What to do:
- Restart the device from Power Control.
- If the warning still appears after restarting, contact technical support.
- Until it's fixed, you can go to G-Sensor Settings, turn off auto-rotation, and use "Fixed Orientation" instead so the image stays in the correct direction.
Real-time clock (RTC) fault
The real-time clock chip was not detected. Automatic recovery was attempted but did not succeed. Time correction while the device is offline may be inaccurate. Restart the device; if this message still appears after restarting, contact technical support.
Impact:
- The automatic wake-up from sleep can't be set. When there are enabled schedules, the device doesn't go to sleep, so that a schedule is never left unable to wake it (it also tries to recover once before going to sleep). When there are no enabled schedules, it sleeps as usual and can only be woken with a physical button.
- The time can't be corrected from the hardware clock, so the system time may gradually drift.
What to do:
- Restart the device.
- If the warning still appears after restarting, contact technical support.
- Until it's fixed, regularly correct the time with "Sync Local Time" in Time Settings.
Cannot identify the panel; refreshing is paused
The TCON firmware version of the panel cannot be read, so the device cannot tell which refresh mode this panel needs and does not refresh it. It keeps retrying automatically. This usually means an incomplete installation or a panel connection problem; if it persists, contact technical support.
Impact:
- Displaying images, schedules and changing images with the buttons don't refresh the panel.
What to do:
- The system retries automatically in the background; once the panel model is read, the warning disappears and refreshing resumes.
- If it keeps appearing, restart the device; if it still appears, contact technical support.
For refresh modes, see Scan direction and refresh mode.
Panel model not supported; refreshing is paused
The model of this panel is not in the compatibility list from the manufacturer, so the device cannot tell which refresh mode it needs and does not refresh it. Contact technical support for a software update.
Impact: Same as above: the panel isn't refreshed.
What to do: Contact technical support and give them "Tcon Firmware Version" from Device info. A software update is usually needed.
Machine data does not match the panel
The model data (screen size) of this device does not match the model reported by the panel. The wrong model settings may have been installed, or the panel was replaced. The device still works, but images and the rescue screen may be the wrong size. Please contact technical support to check the model data.
Impact:
- The device still works, but displayed images may be the wrong size.
What to do: Contact technical support to check the model data.
How the system detects and recovers automatically
This is how the G-Sensor and RTC are checked (for the panel model warnings, see each item above):
- The system keeps checking in the background whether the G-Sensor and RTC can be read.
- When one can't be read, it retries every 2 seconds.
- After 5 consecutive failures, it tries to re-initialize the component automatically, up to 3 times.
- Only if the component still can't be read after 3 re-initializations does the warning appear (about 30 seconds after the fault starts).
- Once the component recovers, the warning disappears automatically.
Most temporary read problems are fixed automatically in step 3, and no warning appears. A warning means automatic recovery didn't succeed.
What to provide when you contact technical support
- When the warning appeared
- Whether it still appears after restarting
- A screenshot of the "About device" page in Device info (device name and all versions)
- WARNING and ERROR level entries from System Logs (you can get them with "Download full logs")
Related sections: Screen orientation and G-Sensor, Time, time zone, and time sync, Sleep and wake-up, Scan direction and refresh mode